| Hardware Specifications | 
| Interface | Copper: 10/100Base-TX RJ-45
 Auto-negotiation/auto-MDI/MDI-X
 802.3at/af PoE Input
 Coaxial:
 BNC, female
 Power over Coaxial output
 DC Socket(Optional):
 52~56V DC input
 DIP-Switch:
 2-position DIP Switch
 ■ Selectable CO or CPE mode
 (Default: CPE)
 ■ Selectable Band plan: asymmetric or symmetric
 (Default: asymmetric)
 | 
| LED Indicators | 
| LED is Green in Color: |  
| System: | PoE: |  
|  | ■ PWR |  | ■ PoE IN |  
| VDSL2: | Ethernet: |  
|  | ■ LNK |  | ■ LNK/ACT |  
|  | ■ CO |  | ■ 100 |  
|  | ■ CPE |  |  |  | 
| ESD Protection | 2KV DC | 
| EFT Protection | 2KV DC | 
| Enclosure | IP30 metal case | 
| Installation | Wall mount or DIN rail with optional kit | 
| Dimensions (W x D x H) | 94 x 70.3x 39.2 mm | 
| Weight | 288g | 
| Power Requirements | ■ RJ-45 PoE Input: 802.3at/af 44~57V DC ■ DC Input: 52~56V DC
 | 
| Power over Ethernet/Coaxial | 
| PoE Standard | IEEE 802.3at Type 2 IEEE 802.3af
 | 
| PSE Interface | BNC 44~57V DC
 (Depending on what the DC/PoE Power Input is)
 | 
| PD Interface | RJ-45, both Mid-Span and End-Span Input Range: 44~57V DC
 | 
| DC Power Output | - | 
| Max. PoE Budget | Power Input by PoE BNC : 25 watts
 Power Input by DC
 BNC : 30 watts
 | 
| Performance* (Downstream / Upstream)**
 | 
| Distance | Data Rate | VC-203PR PoE Output |  
| Asymmetric Mode | Symmetric Mode | VC-203PTW/DC IN
 | VC-203PTW/PoE+ IN
 |  
| 200m | 100/60 Mbps | 90/100 Mbps | 20W | 13W |  
| 400m | 95/55 Mbps | 85/100 Mbps | 16W | 11W |  
| 600m | 90/50 Mbps | 70/80 Mbps | 12W | 10W |  
| 800m | 85/45 Mbps | 65/70 Mbps | 7W | 6W |  
| 1000m | 70/35 Mbps | 55/55 Mbps | 5W | 4W |  
| 1200m | 60/25 Mbps | 45/40 Mbps | - | - |  | 
| Standards Conformance | 
| Standards Compliance | IEEE 802.3 10Base-T Ethernet IEEE 802.3u 100Base-TX Fast Ethernet
 IEEE 802.3af Power over Ethernet (802.3at Type 1)
 IEEE 802.3at Power over Ethernet (802.3at Type 2)
 | 
| Regulation Compliance | FCC Part 15 Class A, CE | 
| Environment | 
| Temperature | 
| Operating: | -40 ~ 75 degree C |  
| Storage: | -40 ~ 75 degrees C |  | 
| Humidity | 
| Operating: | 5 ~ 95% (non-condensing) |  
| Storage: | 5 ~ 95% (non-condensing) |  | 
| * The actual data rate will vary on the quality of the copper wire and environment factors. | 
| ** Default Downstream VC-203PR to VC-203PT ; Upstream VC-203PT to VC-203PR. |